SEW-Taiwan

3 Wire (Analogue) Earth Resistance Testers

  • Filter

● High quality Taut Band movement.● Capable of measuring earth resistance and earth voltage. ● The timer operates automatically for about three to    five minutes when the “PUSH BUTTON SWITCH”    and “TIMER ON BUTTON” are pressed together.  ● This will keep test “ON” for the duration of the timer.● Battery check function. ● Calibration performed with supplied test leads.     SPECIFICATIONS         Measuring ranges Earth resistance 0-10Ω / 0-100Ω / 0-1000Ω Earth voltage 0-30 Vac (40-500Hz) Accuracy Earth resistance ±3% of full scale Earth voltage ±2.5% of full scale Measuring system Earth resistance by constant current inverter 820 Hz, 2mA approx. Open circuit indication LED will be unlit Dimensions 163(L) × 100(W) × 50(D)mm Weight (battery included) Approx. 460g Power source 1.5V (AA) × 6 Safety standards IEC 1010 CAT II 30V

● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth   resistance without tripping earth leakage current   breakers in the circuit under test.● In addition to facilitating for precision measurement,    test leads for simplified two-wire measuring system    also are supplied as standard accessories.● Battery operated.● Battery life indicator.   ● Calibration performed with supplied test leads.     SPECIFICATIONS         Measuring ranges Earth resistance 0-12Ω / 0-120Ω / 0-1200Ω Earth voltage 0-30 Vac (40-500Hz) Accuracy Earth resistance ±3% of full scale Earth voltage ±2.5% of full scale Measuring system Earth resistance by constant current inverter 820 Hz, 2mA approx. Open circuit indication LED will be unlit Dimensions 175(L) × 85(W) × 75(D)mm Weight (battery included) Approx. 600g Power source 1.5V (AA) × 8 Safety standards EN 61010-1 CAT IV 30V   EN 61326-1

● High quality Taut Band movement.● Capable of measuring earth resistance and earth voltage. ● 2mA measuring current permits the testing of earth   resistance without tripping earth leakage current   breakers in the circuit under test.● Test leads are supplied as standard accessories    for simplified two-wire measuring system.● Battery operated.● Battery check function. ● Calibration performed with supplied test leads.     SPECIFICATIONS         Measuring ranges Earth resistance 0-10Ω / 0-100Ω / 0-1000Ω Earth voltage 0-30 Vac (40-500Hz) Accuracy Earth resistance ±3% of full scale Earth voltage ±2.5% of full scale Measuring system Earth resistance by constant current inverter 820Hz, 2mA approx. Open circuit indication LED will be unlit Dimensions 170(L) × 165(W) × 92(D)mm Weight (battery included) Approx. 1000g Power source 1.5V (AA) × 8 Safety standards EN 61010-1 CAT III 150V EN 61326-1

● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth   resistance without tripping earth leakage current   breakers in the circuit under test.● In addition to facilitating for precision measurement,    test leads for simplified two-wire measuring system    also are supplied as standard accessories.● Battery operated.● Battery life indicator.   ● Calibration performed with supplied test leads.     SPECIFICATIONS         Measuring ranges Earth resistance 0-12Ω / 0-120Ω / 0-1200Ω Earth voltage 0-30 Vac (40-500Hz) Accuracy Earth resistance ±3% of full scale Earth voltage ±2.5% of full scale Measuring system Earth resistance by constant current inverter 820 Hz, 2mA approx. Open circuit indication LED will be unlit Dimensions 210(L) × 210(W) × 100(D)mm Weight (battery included) Approx. 1370g Power source 1.5V (AA) × 8 Safety standards EN 61010-1 CAT III 30V EN 61326-1

● High quality Taut Band movement.● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth   resistance without tripping earth leakage current   breakers in the circuit under test.● Test leads are supplied as standard accessories    for simplified two-wire measuring system.● Battery operated.● Battery check function. ● Calibration performed with supplied test leads.     SPECIFICATIONS         Measuring ranges Earth resistance 0-10Ω / 0-100Ω / 0-1000Ω Earth voltage 0-30 Vac (40-500Hz) Accuracy Earth resistance ±3% of full scale Earth voltage ±2.5% of full scale Measuring system Earth resistance by constant current inverter 820 Hz, 2mA approx Open circuit indication LED will be unlit Dimensions 205(L) × 90(W) × 55(D)mm Weight (battery included) Approx. 514g Power source 1.5V (AA) × 6 Safety standards EN 61010-1 CAT III 30V EN 61326-1

● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth   resistance without tripping earth leakage current   breakers in the circuit under test.● In addition to facilitating for precision measurement,    test leads for simplified two-wire measuring system    also are supplied as standard accessories.● Battery operated.● Battery life indicator.   ● Calibration performed with supplied test leads.     SPECIFICATIONS         Measuring ranges Earth resistance 0-12Ω / 0-120Ω / 0-1200Ω Earth voltage 0-30 Vac(40-500Hz) Accuracy Earth resistance ±3% of full scale Earth voltage ±2.5% of full scale Measuring system Earth resistance by constant current inverter 820 Hz, 2mA approx. Open circuit indication LED will be unlit Dimensions 250(L) × 190(W) × 110(D)mm Weight (battery included) Approx. 1500g Power source 1.5V (AA) × 8 Safety standards EN 61010-1 CAT III 30V EN 61326-1