GW INSTEK GOS-6200

Features

* 200MHz Bandwidth, Dual Channel, Delayed Sweep 
* Auto Set 
* Built-in 6 Digits Counter 
* Cursor Readout with 7 Measurements 
* 10 Sets Memory for Front Panel Setting Save & Recall 
* TV-Line Selection (NTSC, PAL, SECAM) 
* Panel Setup Lock of Digital-Control Functions 
* Buzzer Alarm 
* LED Indicators

Description :

The GOS-6200 Analog Oscilloscope satisfies the massive needs for diverse professional applications up to 200MHz. Embedded with Delay Sweep and Hold Off features, the GOS-6200 is capable of measuring sophisticated signals. The Cursor Readout with 7 measurements, Panel Setup Save/Recall, and the built-in 6 Digit Universal Counter all make waveform observation and measurement easier, faster and more accurate. The advanced Time Base Auto Range function acquires waveforms only with one push of a button. The Counter function, 10 memory settings, and advanced Auto functions are among some of the extra benefits available in GOS-6200.

 

Specification : 

CRT

Type 6-inch rectangular type with internal graticule;
0%, 10%, 90% and 100% markers
8 x 10 div (1 div = 1 cm)
Accelerating Potential 14 kV approx.
Illumination Continuously adjustable
Z-axis input Coupling : DC
Sensitivity: 5V or more
Maximum input voltage : 30V (DC + AC peak) at 1kHz or less 
Bandwidth : DC ~ 5 MHz

VERTICAL SYSTEM

Sensitivity 2mV~5V/div, 11 step in 1-2-5 sequence
Sensitivity Accuracy ≦3% (5div at the center of display)
Vernier Vertical Sensitivity Continuously variable to 1/2.5 or less of panel-indicated value
Bandwidth(-3dB) DC~200MHz (5mV/div:DC~150MHz) ; (2mV/div:DC~20MHz)
Rise Time 1.75ns (5mV/div:2.33ns, 2mV/div:17.5ns)
Signal Delay Leading edge can be monitored
Max. Input Voltage 400V(DC+AC peak) at 1kHz or less
Input Coupling AC, DC, GND
Input Impedance 1MΩ ±2% // approx. 25pF
Vertical Mode CH1,CH2,DUAL(CHOP/ALT), ADD, CH2 INV.
Bandwidth Limited 20MHz
Common-Mode Rejection Ratio 50:1 or better at 50kHz
Dynamic Range 8 div at 100MHz; 5div at 200MHz

HORIZONTAL SYSTEM

Horizontal Modes MAIN(A), ALT, DELAY(B)
A(main) Sweep Time 20ns~0.5s/div, continuously variable (UNCAL)
B(delay) Sweep Time 20ns~50ms/div
Accuracy ±3% ( ±5% at x 10 MAG)
Sweep Magnification x 10 (maximum sweep time 2ns/div)
Hold Off Time Variable
Delay Time 1μs~5s
Delay Jitter Better than 1:20000
Alternate Separation Variable

TRIGGER

Trigger Modes AUTO, NORM,TV
Trigger Source CH1, CH2, LINE, EXT, EXT/10
Trigger Coupling AC, DC, HFR, LFR, NR
Trigger Slope "+" or "-" polarity or TVsync polarity
Trigger Sensitivity
Mode Frequency INT EXT EXT/10
AUTO 10Hz~20MHz
20MHz~200MHz
0.35div
1.5div
50mV
150mV
500mV
1.5V
NORM DC~20MHz
20MHz~200MHz
0.35div
1.5div
50mV
150mV
500mV
1.5V
TV sync signal 1div 200mVpp 2Vpp
Trigger Level Range INT: ±4div or more; EXT: ±0.4V or more; EXT/10: ±4V or more

TV Triggering

Mode:TV-V, TV-H, TV-LINE
TV-Line Selection
Standard Field 1 Field 2
NTSC (525H) 1H ~ 263H 1H ~ 262H
PAL (625H) 1H ~ 313H 1H ~ 312H
SECAM (625H)
Max. External Input Voltage 400V(DC+AC peak) at 1kHz
External Input Impedance 1MΩ±5% // approx.25pF

X-Y OPERATION

Mode

X-axis: selectable CH1, EXT, EXT/10
Y-axis: selectable CH1, CH2, CH1 and CH2

Sensitivity Accuracy 2mV~5V/div±3%
EXT : 0.1V/div±5%
EXT/10 : 1V/div±5%
X-axis Bandwidth DC~500kHz(-3dB)
Phase Error 3° or less from DC~50kHz

OUTPUT SIGNAL

Ch1 Signal Output Voltage: approx. 25mV/div into 50Ω
Frequency response : DC ~ 10MHz
Calibrator Output 1kHz Square wave, 2Vpp±2%

CURSOR READOUT FUNCTION

Cursor Measurement Function
 
ΔV, ΔV%, ΔVdB, ΔT, 1/ ΔT, ΔT%, Δθ
Cursor Resolution 1/100 DIV
Effective Cursor Range Vertical: ±3div ; Horizontal: ±4 div
Panel Setting Display Vertical: V/div(CH1,CH2),UNCAL,ALT/CHOP/ADD,INV, probe factor,AC/DC/GND
Horizontal: s/div(MTB, DTB), UNCAL, x 10MAG, Delay time, Hold-off
Trigger: source, coupling, slope, level, TV-V, TV-H
Others: X-Y, lock, save/recall MEM 0-9

AUTO MEASUREMENT FUNCTION
 

Parameter Function FREQ, PERIOD,±WIDTH,±DUTY (+ or - polarity selected by trigger slope)
Display Digits Max. 6-digits, decimal
Frequency Range 50Hz ~ 200MHz
Accuracy 1kHz ~ 200MHz : ±0.01% ; 50Hz ~ 1kHz : ±0.05%
Measuring Sensitivity > 2 div (Measuring source selected from CH1 and Ch2 as synchronous signal sources)

SPECIAL FUNCTION

Auto Set Input Channel : CH1, CH2
Frequency Response 50Hz ~ 50MHz
Panel Setting Save & Recall 10 sets
Panel Setups Lock Provided
POWER SOURCE  
  AC 100V/120V/230V±10% , 50/60Hz
  User manual x 1
Power cord x 1
GTP-250A: 250MHz Probe (10:1/1:1) Switchable Passive Probe (One per channel)
DIMENSIONS & WEIGHT  
  310(W) x 150(H) x 470(D) mm
Approx. 9kg

Acccessories : 

User manual x 1
Power cord x 1
GTP-250A: 250MHz Probe (10:1/1:1) Switchable Passive Probe (One per channel)

Optional Accessories
GTL-110
  Test lead, BNC-BNC heads
GTC-001  Instrument cart, 450(W) x 430(D)mm (120V input socket)
GTC-002  Instrument cart, 330(W) x 430(D)mm (120V input socket)

Orddering Information: 

GOS-6200  200MHz cursor readout analog oscilloscope 

Location

Ask about this product
503 Service Unavailable

Service Unavailable

The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.

Additionally, a 503 Service Unavailable error was encountered while trying to use an ErrorDocument to handle the request.