TES-Taiwan

Flexible AC Current Clamp

  • Filter

True RMS 3000A Voltage Measurement (AFLEX 3002 only) Fast Peak Function(30 μs) MAX/MIN Auto-Power-Off:30 minutes Flexible probe, different from normal clamp meter, can pass through obstacles at will and wind many conducting wires simultaneously, max. diameter 170mm

Power Analysis (3005) W, KW, H.P. VA ,KVA, VAR, KVAR PF, Phase Angle( Φ ) Energy (WH, KWH) Dual displays (W+PF, VA+KVAR) Balanced 3 Φ Power Quality and Sequence Harmonics Analysis True RMS (V and A) 3000 A Non-interrupted Harmonic Analysis ( V and A ) to the 50th Order in % and Magnitude Analysis of % THD-F and C.F. Fast Peak Function (33μs and 39μs) Programmable PT (1 to 250 )ratios Auto - Power - Off : 30 Minutes

Display of Overlapped Voltage and Current Waveform Maximum Demand (MD in W, KW, MW) with Programmable Period Harmonics Analysis ( V and I ) to the 50th Order Display of 25 Harmonics in One Screen with Waveform Display of waveform with Peak Values (512 Samples / Period), Datalogging of 32, 64, 128 or 256 Points/Cycles Analysis of Total Harmonics Distortion ( % THD-F ) Graphic Phasor Diagram Programmable PT (1 to 3000) Ratios Capture 128 Transient Events ( Time + Cycles + Faults ) with Programmable Threshold(%), Can Also be Reviewed in LCD 50000 Records with Programmable Interval ( 1 to 6000 seconds) Output of Waveform, Power Parameters and 50 Harmonics at Command. Large Dot Matrix LCD Display with Backlight Optical Isolated RS-232C Interface Smart Datalogging to save Battery Power for Long-term Monitoring Built - in Calendar Clock for Data Logging